<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd"
	xmlns:media="http://search.yahoo.com/mrss/"
>

<channel>
	<title>Airtrade Systems &#187; Commercial Buildings</title>
	<atom:link href="http://www.airtrade.com.sg/category/commercial-buildings/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.airtrade.com.sg</link>
	<description>The Reliable Name for Air Movement, Quality Products with Prompt &#38; Efficient Service</description>
	<lastBuildDate>Thu, 20 May 2010 07:57:48 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<!-- podcast_generator="podPress/8.8" -->
		<copyright>&#xA9; </copyright>
		<managingEditor>lionel@ripplewerkz.com ()</managingEditor>
		<webMaster>lionel@ripplewerkz.com()</webMaster>
		<category></category>
		<itunes:keywords></itunes:keywords>
		<itunes:subtitle></itunes:subtitle>
		<itunes:summary>The Reliable Name for Air Movement, Quality Products with Prompt amp; Efficient Service</itunes:summary>
		<itunes:author></itunes:author>
		<itunes:category text="Society &amp; Culture"/>
		<itunes:owner>
			<itunes:name></itunes:name>
			<itunes:email>lionel@ripplewerkz.com</itunes:email>
		</itunes:owner>
		<itunes:block>No</itunes:block>
		<itunes:explicit>no</itunes:explicit>
		<itunes:image href="http://www.nitrodesigns.com/airtrade/wp-content/plugins/podpress/images/powered_by_podpress_large.jpg" />
		<image>
			<url>http://www.nitrodesigns.com/airtrade/wp-content/plugins/podpress/images/powered_by_podpress.jpg</url>
			<title>Airtrade Systems</title>
			<link>http://www.airtrade.com.sg</link>
			<width>144</width>
			<height>144</height>
		</image>
		<item>
		<title>Hison Axial Flow Fans for Commercial/Industrial</title>
		<link>http://www.airtrade.com.sg/hison-marine-axial-flow-fans/</link>
		<comments>http://www.airtrade.com.sg/hison-marine-axial-flow-fans/#comments</comments>
		<pubDate>Fri, 17 Jul 2009 03:34:24 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Axial Flow Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Hison]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=40</guid>
		<description><![CDATA[Introduction

 Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.
Available from sizes 150mm to 2000mm diameter.
Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.
Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the [...]]]></description>
			<content:encoded><![CDATA[<p><strong><img class="alignright size-full wp-image-456" title="Commercial Axial Flow Fans" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/commercial-axial-flow-fans.jpg" alt="Commercial Axial Flow Fans" width="246" height="225" />Introduction</strong></p>
<ul>
<li> Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.</li>
<li>Available from sizes 150mm to 2000mm diameter.</li>
<li>Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.</li>
<li>Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the blade shank with tapered conical section. The tapered section fits into a conical slot in the hub, providing a taper lock fit. A bolt is cast into the blade, projecting into the hub and is secured on the inside by lock-washer and nut.</li>
<li>Hison Impellers comes in polypropylene and aluminum.</li>
</ul>
<p><strong>Performance</strong></p>
<ul>
<li>Ranges from 100m<sup>3</sup>/hr to 250000m<sup>3</sup>/hr and static pressure up to 125mm.</li>
<li>Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in      accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.</li>
<li>Sound level data is in accordance with BS 848 – 1985: part 2. and  ISO 5136 First Edition 1990-12-15.</li>
</ul>
<p><span id="more-40"></span><strong>Direction of Air Flow</strong></p>
<ul>
<li>Versatility of air flow direction of Form ‘B’ or Form ‘A’</li>
</ul>
<p><strong>Constructions</strong></p>
<ul>
<li>Fan housings are constructed of rolled steel.  Fan housing of 500mm diameter and above of up to 10mm thick shall have rolled integral flanges ensuring complete roundness of the casing and accuracy of bolting holes. 450mm diameter and below shall be welded with rolled flat bar flanges continuous welded on both side.</li>
<li>Blades tip clearance is consistently maintained.</li>
<li>Standard fans are with extended motor leads to fan housing exterior junction box with IP 56 degree of protection.</li>
<li>Extended lubrication tubes from motor to exterior of fan housing are standard for motors with lubrication nipple.</li>
</ul>
<p><strong>Balancing Standards</strong></p>
<ul>
<li>All fan impellers are statically and dynamically balance to ISO 1940-1973 (E) G:6.3 standard.</li>
</ul>
<p><strong>Standard Surface Coating</strong></p>
<ul>
<li>Hot Dipped Galvanised to EN ISO 461:1999 which also comply to ASTM A123, A153 and BS 729.</li>
<li>Special painting to user specification is available upon request.</li>
</ul>
<p><strong>Motors</strong></p>
<ul>
<li>All fans shall be supplied with totally enclosed, high efficiency motors of IP 55 degree of protection, foot-mounted Class F insulation, built to International Standards (IEC)</li>
<li>Special motors such as Explosion proof, 2-speed, Class H or D.C. motors are available to suits each specific application.</li>
</ul>
<p><strong>Factory Acceptance Tests</strong></p>
<ul>
<li>All HISON Fans are checked and tested under the strict ISO procedures undertaken for a Standard Factory Acceptance Test (FAT) before delivery.</li>
</ul>
<p><strong>Accessories</strong></p>
<ul>
<li>Separate upstream and downstream guides vanes</li>
<li>Mounting Feet</li>
<li>Inlet Cone</li>
<li>Matching Flanges</li>
<li>Wire Guards</li>
<li>Anti-Vibration Mountings</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/hison-marine-axial-flow-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hison Axial Flow Fans with Spark Resistant Constructions</title>
		<link>http://www.airtrade.com.sg/hison-axial-flow-fans-spark-resistant-constructions/</link>
		<comments>http://www.airtrade.com.sg/hison-axial-flow-fans-spark-resistant-constructions/#comments</comments>
		<pubDate>Fri, 24 Jul 2009 09:33:24 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Axial Flow Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Marine Industries]]></category>
		<category><![CDATA[Offshore Industries]]></category>
		<category><![CDATA[Hison]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=349</guid>
		<description><![CDATA[Introduction

 Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.
Available from sizes 300mm to 2000mm diameter.
Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.
Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the [...]]]></description>
			<content:encoded><![CDATA[<p><strong><img class="alignright size-full wp-image-454" title="Spark Resistant Construction Fan" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/spark-resistant-construction-fan.jpg" alt="Spark Resistant Construction Fan" width="219" height="213" />Introduction</strong></p>
<ul>
<li> Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.</li>
<li>Available from sizes 300mm to 2000mm diameter.</li>
<li>Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.</li>
<li>Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the blade shank with tapered conical section. The tapered section fits into a conical slot in the hub, providing a taper lock fit. A bolt is cast into the blade, projecting into the hub and is secured on the inside by lock-washer and nut.</li>
<li>Hison Impellers comes in aluminum.</li>
</ul>
<p><strong>Spark Resistant Constructions</strong></p>
<ul>
<li><img class="alignright size-full wp-image-612" title="baseefa-logo" src="http://www.airtrade.com.sg/wp-content/uploads/2009/07/baseefa-logo.jpg" alt="baseefa-logo" />Hison Axial Flow Fans with Explosion Proof Motor and Spark Resistant Construction (SRC) features can be built in compliance and bear the BASEFA &#8216;ATEX&#8217; 0299X and 0300X certification or the Standard Spark Resistant Construction (SRC) which is built in accordance to AMCA Standard 99-0401-80 Type B Spark Resistant Construction.</li>
<li>Extended leads extended to outside of casing in accordance to Explosion proof procedure to explosion proof external fan junction box.</li>
<li>Anti-Spark Ring on standard fans is available on request.</li>
</ul>
<p><span id="more-349"></span><strong>Performance</strong></p>
<ul>
<li>Ranges from 100m<sup>3</sup>/hr to 250000m<sup>3</sup>/hr and static pressure up to 125mm.</li>
<li>Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in      accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.</li>
<li>Sound level data is in accordance with BS 848 – 1985: part 2. and  ISO 5136 First Edition 1990-12-15.</li>
</ul>
<p><strong>Direction of Air Flow</strong></p>
<ul>
<li>Versatility of air flow direction of Form ‘B’ or Form ‘A’</li>
</ul>
<p><strong>Constructions</strong></p>
<ul>
<li>Fan housings are constructed of rolled steel.  Fan housing of 500mm diameter and above of up to 10mm thick shall have rolled integral flanges ensuring complete roundness of the casing and accuracy of bolting holes. 450mm diameter and below shall be welded with rolled flat bar flanges continuous welded on both side.</li>
<li>Blades tip clearance is consistently maintained.</li>
<li>Extended lubrication tubes from motor to exterior of fan housing are standard for motors with lubrication nipple.</li>
</ul>
<p><strong>Balancing Standards</strong></p>
<ul>
<li>All fan impellers are statically and dynamically balance to ISO 1940-1973 (E) G:6.3 standard.</li>
</ul>
<p><strong>Standard Surface Coating</strong></p>
<ul>
<li>Hot Dipped Galvanised to EN ISO 461:1999 which also comply to ASTM A123, A153 and BS 729.</li>
<li>Special painting to user specification is available upon request.</li>
</ul>
<p><strong>Motors</strong></p>
<ul>
<li>Motors supplied can be suitable for hazardous areas.</li>
</ul>
<p><strong>Factory Acceptance Tests</strong></p>
<ul>
<li>All HISON Fans are checked and tested under the strict ISO procedures undertaken for a Standard Factory Acceptance Test (FAT) before delivery.</li>
</ul>
<p><strong>Accessories</strong></p>
<ul>
<li>Separate upstream and downstream guides vanes</li>
<li>Mounting Feet</li>
<li>Inlet Cone</li>
<li>Matching Flanges</li>
<li>Wire Guards</li>
<li>Anti-Vibration Mountings</li>
</ul>
<p><a href="http://www.airtrade.com.sg/wp-content/uploads/2009/07/baseefa-doc1.jpg"><img class="aligncenter size-full wp-image-617" title="baseefa-doc_sm" src="http://www.airtrade.com.sg/wp-content/uploads/2009/07/baseefa-doc_sm.jpg" alt="Hison Axial Flow Fans with Explosion Proof Motor and Spark Resistant Construction (SRC) features can be built in compliance and bear the BASEFA 'ATEX' 0299X and 0300X certification or the Standard Spark Resistant Construction (SRC) which is built in accordance to AMCA Standard 99-0401-80 Type B Spark Resistant Construction." /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/hison-axial-flow-fans-spark-resistant-constructions/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hison Bifurcated Fans</title>
		<link>http://www.airtrade.com.sg/bifurcated-fans/</link>
		<comments>http://www.airtrade.com.sg/bifurcated-fans/#comments</comments>
		<pubDate>Fri, 17 Jul 2009 01:16:55 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Axial Flow Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Hison]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=163</guid>
		<description><![CDATA[Hison Bifurcated Fans, splitway with motor out of air stream are designed to meet difficult operating conditions, like movement of

 heated and hot air/gas
hazardous air
kitchen exhaust system
corrosive or contaminated properties
alternate to flame proof motors

Performance

Ranges from 100m3/hr to 250000m3/hr and static pressure up to 125mm.
Performance of Hison Fans are tested in accordance to BS 848 Part [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-thumbnail wp-image-164" title="Bifurcated Fans" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/bifurcatedfans-180x180.jpg" alt="Bifurcated Fans" width="180" height="180" />Hison Bifurcated Fans, splitway with motor out of air stream are designed to meet difficult operating conditions, like movement of</p>
<ul>
<li> heated and hot air/gas</li>
<li>hazardous air</li>
<li>kitchen exhaust system</li>
<li>corrosive or contaminated properties</li>
<li>alternate to flame proof motors</li>
</ul>
<p><strong>Performance</strong></p>
<ul>
<li>Ranges from 100m<sup>3</sup>/hr to 250000m<sup>3</sup>/hr and static pressure up to 125mm.</li>
<li>Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.</li>
<li>Sound level data is in accordance with BS 848 – 1985: part 2. and  ISO 5136 First Edition 1990-12-15.</li>
</ul>
<p><span id="more-163"></span></p>
<p><img title="More..." src="http://www.nitrodesigns.com/airtrade/wp-includes/js/tinymce/plugins/wordpress/img/trans.gif" alt="" /><strong>Direction of Air Flow</strong></p>
<ul>
<li>Versatility of air flow direction of Form ‘B’ or Form ‘A’</li>
</ul>
<p><strong>Constructions</strong></p>
<ul>
<li>Fan housings are constructed of rolled steel. Fan housing of 500mm diameter and above of up to 10mm thick shall have rolled integral flanges ensuring complete roundness of the casing and accuracy of bolting holes. 450mm diameter and below shall be welded with rolled flat bar flanges continuous welded on both side.</li>
<li>Blades tip clearance is consistently maintained.</li>
<li>Standard fans are with extended motor leads to fan housing exterior junction box with IP 56 degree of protection.</li>
<li>Extended lubrication tubes from motor to exterior of fan housing are standard for motors with lubrication nipple.</li>
</ul>
<p><strong>Balancing Standards</strong></p>
<ul>
<li>All fan impellers are statically and dynamically balance to ISO 1940-1973 (E) G:6.3 standard.</li>
</ul>
<p><strong>Standard Surface Coating</strong></p>
<ul>
<li>Hot Dipped Galvanised to EN ISO 461:1999 which also comply to ASTM A123, A153 and BS 729.</li>
<li>Special painting to user specification is available upon request.</li>
</ul>
<p><strong>Motors</strong></p>
<ul>
<li>All fans shall be supplied with totally enclosed, high efficiency motors of IP 55 degree of protection, foot-mounted Class F insulation, built to International Standards (IEC)</li>
<li>Special motors such as Explosion proof, 2-speed, Class H or D.C. motors are available to suits each specific application.</li>
</ul>
<p><strong>Factory Acceptance Tests</strong></p>
<ul>
<li>All HISON Fans are checked and tested under the strict ISO procedures undertaken for a Standard Factory Acceptance Test (FAT) before delivery.</li>
</ul>
<p><strong>Accessories</strong></p>
<ul>
<li>Separate upstream and downstream guides vanes</li>
<li>Mounting Feet</li>
<li>Inlet Cone</li>
<li>Matching Flanges</li>
<li>Wire Guards</li>
<li>Anti-Vibration Mountings</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/bifurcated-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hison Plated Mounted Fans</title>
		<link>http://www.airtrade.com.sg/plated-mounted-fans/</link>
		<comments>http://www.airtrade.com.sg/plated-mounted-fans/#comments</comments>
		<pubDate>Fri, 24 Jul 2009 10:38:00 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Axial Flow Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Marine Industries]]></category>
		<category><![CDATA[Offshore Industries]]></category>
		<category><![CDATA[Hison]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=377</guid>
		<description><![CDATA[Introduction

 Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.
Available from sizes 150mm to 1250mm diameter.
Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.
Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the [...]]]></description>
			<content:encoded><![CDATA[<p><strong><img class="alignright size-full wp-image-378" title="Plated Mounted Fans" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/platemountedfans.jpg" alt="Plated Mounted Fans" width="200" height="200" />Introduction</strong></p>
<ul>
<li> Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.</li>
<li>Available from sizes 150mm to 1250mm diameter.</li>
<li>Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.</li>
<li>Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the blade shank with tapered conical section. The tapered section fits into a conical slot in the hub, providing a taper lock fit. A bolt is cast into the blade, projecting into the hub and is secured on the inside by lock-washer and nut.</li>
<li>Hison Impellers comes in polypropylene and aluminum.</li>
</ul>
<p><strong>Performance</strong></p>
<ul>
<li>Ranges from 100m<sup>3</sup>/hr to 250000m<sup>3</sup>/hr and static pressure up to 125mm.</li>
<li>Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in      accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.</li>
<li>Sound level data is in accordance with BS 848 – 1985: part 2. and  ISO 5136 First Edition 1990-12-15.</li>
</ul>
<p><span id="more-377"></span><strong>Direction of Air Flow</strong></p>
<ul>
<li>Versatility of air flow direction of Form ‘B’ or Form ‘A’</li>
</ul>
<p><strong>Constructions</strong></p>
<ul>
<li>Fan housings are constructed of rolled steel.  Fan housing of 500mm diameter and above of up to 10mm thick shall have rolled integral flanges ensuring complete roundness of the casing and accuracy of bolting holes. 450mm diameter and below shall be welded with rolled flat bar flanges continuous welded on both side.</li>
<li>Blades tip clearance is consistently maintained.</li>
<li>Standard fans are with extended motor leads to fan housing exterior junction box with IP 56 degree of protection.</li>
<li>Extended lubrication tubes from motor to exterior of fan housing are standard for motors with lubrication nipple.</li>
<li>Spark Resistance Construction ring available upon request.</li>
<li>Fans are installed with protective wire-mesh guard</li>
</ul>
<p><strong>Balancing Standards</strong></p>
<ul>
<li>All fan impellers are statically and dynamically balance to ISO 1940-1973 (E) G:6.3 standard.</li>
</ul>
<p><strong>Standard Surface Coating</strong></p>
<ul>
<li>Hot Dipped Galvanised to EN ISO 461:1999 which also comply to ASTM A123, A153 and BS 729.</li>
<li>Special painting to user specification is available upon request.</li>
</ul>
<p><strong>Motors</strong></p>
<ul>
<li>All fans shall be supplied with totally enclosed, high efficiency motors of IP 55 degree of protection, foot-mounted Class F insulation, built to International Standards (IEC)</li>
<li>Special motors such as Explosion proof, 2-speed, Class H or D.C. motors are available to suits each specific application.</li>
</ul>
<p><strong>Factory Acceptance Tests</strong></p>
<ul>
<li>All HISON Fans are checked and tested under the strict ISO procedures undertaken for a Standard Factory Acceptance Test (FAT) before delivery.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/plated-mounted-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hison Belt-Driven Axial Fans</title>
		<link>http://www.airtrade.com.sg/belt-driven-fans/</link>
		<comments>http://www.airtrade.com.sg/belt-driven-fans/#comments</comments>
		<pubDate>Fri, 17 Jul 2009 01:25:46 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Axial Flow Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Hison]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=168</guid>
		<description><![CDATA[Designed for application where motors need to be outside system airstream. Hison belt driven fans are ideal for moisture laden or dust laden or where system exhausts heated air
Performance

Ranges from 100m3/hr to 250000m3/hr and static pressure up to 125mm.
Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-thumbnail wp-image-169" title="Belt Driven" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/belt-driven-180x180.jpg" alt="Belt Driven" width="180" height="180" />Designed for application where motors need to be outside system airstream. Hison belt driven fans are ideal for moisture laden or dust laden or where system exhausts heated air</p>
<p><strong>Performance</strong></p>
<ul>
<li>Ranges from 100m<sup>3</sup>/hr to 250000m<sup>3</sup>/hr and static pressure up to 125mm.</li>
<li>Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in      accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.</li>
<li>Sound level data is in accordance with BS 848 – 1985: part 2. and  ISO 5136 First Edition 1990-12-15.<span id="more-168"></span></li>
</ul>
<p><img title="More..." src="http://www.nitrodesigns.com/airtrade/wp-includes/js/tinymce/plugins/wordpress/img/trans.gif" alt="" /><strong>Direction of Air Flow</strong></p>
<ul>
<li>Versatility of air flow direction of Form ‘B’ or Form ‘A’</li>
</ul>
<p><strong>Constructions</strong></p>
<ul>
<li>Fan housings are constructed of rolled steel. Fan housing of 500mm diameter and above of up to 10mm thick shall have rolled integral flanges ensuring complete roundness of the casing and accuracy of bolting holes. 450mm diameter and below shall be welded with rolled flat bar flanges continuous welded on both side.</li>
<li>Blades tip clearance is consistently maintained.</li>
<li>Standard fans are with extended motor leads to fan housing exterior junction box with IP 56 degree of protection.</li>
<li>Extended lubrication tubes from motor to exterior of fan housing are standard for motors with lubrication nipple.</li>
</ul>
<p><strong>Balancing Standards</strong></p>
<ul>
<li>All fan impellers are statically and dynamically balance to ISO 1940-1973 (E) G:6.3 standard.</li>
</ul>
<p><strong>Standard Surface Coating</strong></p>
<ul>
<li>Hot Dipped Galvanised to EN ISO 461:1999 which also comply to ASTM A123, A153 and BS 729.</li>
<li>Special painting to user specification is available upon request.</li>
</ul>
<p><strong>Motors</strong></p>
<ul>
<li>All fans shall be supplied with totally enclosed, high efficiency motors of IP 55 degree of protection, foot-mounted Class F insulation, built to International Standards (IEC)</li>
<li>Special motors such as Explosion proof, 2-speed, Class H or D.C. motors are available to suits each specific application.</li>
</ul>
<p><strong>Factory Acceptance Tests</strong></p>
<ul>
<li>All HISON Fans are checked and tested under the strict ISO procedures undertaken for a Standard Factory Acceptance Test (FAT) before delivery.</li>
</ul>
<p><strong>Accessories</strong></p>
<ul>
<li>Separate upstream and downstream guides vanes</li>
<li>Mounting Feet</li>
<li>Inlet Cone</li>
<li>Matching Flanges</li>
<li>Wire Guards</li>
<li>Anti-Vibration Mountings</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/belt-driven-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Single-Width Fans with AcoustaFoil&#174;/BC/PLR Wheels</title>
		<link>http://www.airtrade.com.sg/single-width-fans-with-acoustafoilbcplr-wheels/</link>
		<comments>http://www.airtrade.com.sg/single-width-fans-with-acoustafoilbcplr-wheels/#comments</comments>
		<pubDate>Fri, 24 Jul 2009 08:20:01 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Centrifugal Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Marine Industries]]></category>
		<category><![CDATA[New York Blower]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=299</guid>
		<description><![CDATA[New York Blower Single-Width  Fans feature three types of  		backward inclined wheels for maximum selection flexibility and optimum performance: AcoustaFoil®  		wheels with airfoil blades for highest efficiency in clean, dry  		airstreams, PLR wheels with flat, single-thickness blades for best  		performance in moist or mildly contaminated airstreams, and BC wheels  		with [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-300" title="Single-Width Fans" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/single-width-fans.jpg" alt="Single-Width Fans" width="220" height="188" />New York Blower Single-Width  Fans feature three types of  		backward inclined wheels for maximum selection flexibility and optimum performance: AcoustaFoil®  		wheels with airfoil blades for highest efficiency in clean, dry  		airstreams, PLR wheels with flat, single-thickness blades for best  		performance in moist or mildly contaminated airstreams, and BC wheels  		with curved, single-thickness blades for good performance in moist  		airstreams.</p>
<p><strong>VOLUME</strong> &#8211; to 200,000  CFM<br />
<strong>PRESSURES</strong> &#8211; to 14&#8243; WG<br />
<strong>TEMPERATURES</strong> &#8211; to 650°F</p>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/single-width-fans-with-acoustafoilbcplr-wheels/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Double Width Double Inlet Centrifugal Fans</title>
		<link>http://www.airtrade.com.sg/double-width-double-inlet-centrifugal-fans/</link>
		<comments>http://www.airtrade.com.sg/double-width-double-inlet-centrifugal-fans/#comments</comments>
		<pubDate>Fri, 24 Jul 2009 08:31:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Centrifugal Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[New York Blower]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=316</guid>
		<description><![CDATA[New York Blower Double-Width AcoustaFoil® Fans combine the efficiency of airfoil wheels with construction to suit industrial supply and exhaust applications as well as commercial heating, ventilating and air-conditioning systems.
VOLUME - to 350,000  CFM
PRESSURES - to 14&#8243; WG
TEMPERATURES - to 120°F
]]></description>
			<content:encoded><![CDATA[<p align="justify"><img class="alignright size-full wp-image-317" title="Double Width Double Inlet Centrifugal Fans" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/double-width.jpg" alt="Double Width Double Inlet Centrifugal Fans" width="234" height="254" />New York Blower Double-Width AcoustaFoil® Fans combine the efficiency of airfoil wheels with construction to suit industrial supply and exhaust applications as well as commercial heating, ventilating and air-conditioning systems.</p>
<p align="justify"><strong>VOLUME </strong>- to 350,000  CFM<br />
<strong>PRESSURES </strong>- to 14&#8243; WG<br />
<strong>TEMPERATURES </strong>- to 120°F</p>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/double-width-double-inlet-centrifugal-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Junior Fans</title>
		<link>http://www.airtrade.com.sg/junior-fans/</link>
		<comments>http://www.airtrade.com.sg/junior-fans/#comments</comments>
		<pubDate>Fri, 24 Jul 2009 09:04:19 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Centrifugal Fans]]></category>
		<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Marine Industries]]></category>
		<category><![CDATA[New York Blower]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=341</guid>
		<description><![CDATA[New York Blower Junior Fans with forward-curve wheels are well suited to ventilation and industrial-process applications where moderate capacities at low pressures are required. Applications include HVAC ventilation, oven and dryer exhaust and process drying and cooling.
VOLUME - to 4600  CFM
PRESSURES - to 2-1/2&#8243; WG
TEMPERATURES - to 450°F
]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-342" title="junior Fans" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/junior.jpg" alt="junior Fans" width="187" height="190" />New York Blower Junior Fans with forward-curve wheels are well suited to ventilation and industrial-process applications where moderate capacities at low pressures are required. Applications include HVAC ventilation, oven and dryer exhaust and process drying and cooling.</p>
<p><strong>VOLUME </strong>- to 4600  CFM<br />
<strong>PRESSURES </strong>- to 2-1/2&#8243; WG<br />
<strong>TEMPERATURES </strong>- to 450°F</p>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/junior-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Silencers for Commercial/Industrial</title>
		<link>http://www.airtrade.com.sg/silencers/</link>
		<comments>http://www.airtrade.com.sg/silencers/#comments</comments>
		<pubDate>Thu, 16 Jul 2009 12:55:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Silencers & Attenuators]]></category>
		<category><![CDATA[Barclay Engineering]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=24</guid>
		<description><![CDATA[Rectangular and Cylindrical Silencers
Rectangular and cylindrical silencers are used to reduce the noise in “air moving” applications such as air conditioning or ventilation systems, fan and blower inlets and outlets, dust control equipment, motor cooling fans, enclosure ventilation and other industrial applications.
Both types of silencers are absorptive, with the rectangular silencer using absorptive splitters to [...]]]></description>
			<content:encoded><![CDATA[<p><strong><a href="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/industrialcommercialsilencers.jpg"><img class="alignright size-full wp-image-535" title="Silencers for Commercial/Industrial" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/industrialcommercialsilencers.jpg" alt="Silencers for Commercial/Industrial" width="250" height="250" /></a>Rectangular and Cylindrical Silencers</strong></p>
<p>Rectangular and cylindrical silencers are used to reduce the noise in “air moving” applications such as air conditioning or ventilation systems, fan and blower inlets and outlets, dust control equipment, motor cooling fans, enclosure ventilation and other industrial applications.</p>
<p>Both types of silencers are absorptive, with the rectangular silencer using absorptive splitters to reduce the noise, while the cylindrical silencer is insulated with acoustic infill and a central-pod is inserted in the silencer for higher attenuation. For industrial applications both the rectangular and cylindrical silencers are made in a heavier construction to suit the application.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/silencers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Acoustic louvres</title>
		<link>http://www.airtrade.com.sg/acoustic-louvres-2/</link>
		<comments>http://www.airtrade.com.sg/acoustic-louvres-2/#comments</comments>
		<pubDate>Fri, 17 Jul 2009 01:40:48 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Commercial Buildings]]></category>
		<category><![CDATA[Industrial]]></category>
		<category><![CDATA[Marine Industries]]></category>
		<category><![CDATA[Offshore Industries]]></category>
		<category><![CDATA[Silencers & Attenuators]]></category>
		<category><![CDATA[Barclay Engineering]]></category>

		<guid isPermaLink="false">http://www.nitrodesigns.com/airtrade/?p=180</guid>
		<description><![CDATA[Acoustic louvres are used to prevent noise breakout from an air inlet or outlet of a plantroom, building or enclosure whilst allowing ventilation air transfer. They have varying acoustic performance depending on the type of aerodynamically designed blades is used and the depth of the acoustic louvre demanded by the design.
Weather louvres resist the ingress [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-thumbnail wp-image-70" title="Acoustic Louvres" src="http://www.nitrodesigns.com/airtrade/wp-content/uploads/2009/07/acoustic-180x180.jpg" alt="Acoustic Louvres" width="180" height="180" />Acoustic louvres are used to prevent noise breakout from an air inlet or outlet of a plantroom, building or enclosure whilst allowing ventilation air transfer. They have varying acoustic performance depending on the type of aerodynamically designed blades is used and the depth of the acoustic louvre demanded by the design.</p>
<p>Weather louvres resist the ingress of rain and moisture and are used where noise is not such a concern or is being treated by some other means. They provide weatherproofing and air transfer and can be made from steel, stainless steel or aluminium and then finished in enamel paint, powdercoated or anodised.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.airtrade.com.sg/acoustic-louvres-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
