New York Blower Single-Width Fans feature three types of backward inclined wheels for maximum selection flexibility and optimum performance: AcoustaFoil® wheels with airfoil blades for highest efficiency in clean, dry airstreams, PLR wheels with flat, single-thickness blades for best performance in moist or mildly contaminated airstreams, and BC wheels with curved, single-thickness blades for good performance in moist airstreams.
VOLUME – to 200,000 CFM
PRESSURES – to 14″ WG
TEMPERATURES – to 650°F
For any enquries?
Please Contact us
New York Blower Tubular AcoustaFoil™ Fans combine the efficient performance of centrifugal airfoil wheels with the versatility and compactness of axial-flow fan design. Uses include industrial/process supply-and-exhaust applications as well as heating, ventilating and air-conditioning systems.
VOLUME - to 140,000 CFM
PRESSURES - to 14″ WG
TEMPERATURES - to 200°F
For any enquries?
Please Contact us
Introduction
- Hison Axial Flow Fans, formerly know as Howden Fans are manufactured to International Quality Standard.
- Available from sizes 150mm to 2000mm diameter.
- Incorporate heavy duty marine grade LM-6 or equal cast aluminium impellers with aerofoil blades for better efficiencies and lower sound level.
- Adjustable blades angles designs to meet varied volume and pressure system requirements featuring the blade shank with tapered conical section. The tapered section fits into a conical slot in the hub, providing a taper lock fit. A bolt is cast into the blade, projecting into the hub and is secured on the inside by lock-washer and nut.
- Hison Impellers comes in polypropylene and aluminum.
Performance
- Ranges from 100m3/hr to 250000m3/hr and static pressure up to 125mm.
- Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.
- Sound level data is in accordance with BS 848 – 1985: part 2. and ISO 5136 First Edition 1990-12-15.
Read more
For any enquries?
Please Contact us
Acoustic louvres are used to prevent noise breakout from an air inlet or outlet of a plantroom, building or enclosure whilst allowing ventilation air transfer. They have varying acoustic performance depending on the type of aerodynamically designed blades is used and the depth of the acoustic louvre demanded by the design.
Weather louvres resist the ingress of rain and moisture and are used where noise is not such a concern or is being treated by some other means. They provide weatherproofing and air transfer and can be made from steel, stainless steel or aluminium and then finished in enamel paint, powdercoated or anodised.
For any enquries?
Please Contact us
Designed for application where motors need to be outside system airstream. Hison belt driven fans are ideal for moisture laden or dust laden or where system exhausts heated air
Performance
- Ranges from 100m3/hr to 250000m3/hr and static pressure up to 125mm.
- Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.
- Sound level data is in accordance with BS 848 – 1985: part 2. and ISO 5136 First Edition 1990-12-15. Read more
For any enquries?
Please Contact us
Hison Bifurcated Fans, splitway with motor out of air stream are designed to meet difficult operating conditions, like movement of
- heated and hot air/gas
- hazardous air
- kitchen exhaust system
- corrosive or contaminated properties
- alternate to flame proof motors
Performance
- Ranges from 100m3/hr to 250000m3/hr and static pressure up to 125mm.
- Performance of Hison Fans are tested in accordance to BS 848 Part 1 1980, the latest ISO 5801 First Edition 1997-06-1 and many of Hison Axial Fan models are also tested in accordance to AMCA 210-99 Standard for air performance and licensed to bear the AMCA seal.
- Sound level data is in accordance with BS 848 – 1985: part 2. and ISO 5136 First Edition 1990-12-15.
Read more
For any enquries?
Please Contact us
Specially designed for cooling hot spots, cooling, gas freeing and fume removal applications.
Hison Mancoolers aid in the dissipation of body heat through a higher evaporation rate, helping to prevent heat exhaustion and increase personal safety.
Particularly effective for fast turn around, minimising costly down time or where a clean healthy environment must be maintained for the safety of workers
For any enquries?
Please Contact us
Features
- Available for sizes 150mm to 2000mm diameter fans.
- Options for construction materials includes mild steel, stainless steel or aluminum
- Option to integrate with or without built-in damper
- Minimum thickness of 3mm
Standard Surface Coating
- Hot Dipped Galvanised to EN ISO 461:1999 which also comply to ASTM A123, A153 and BS 729.
- Blasted to SA 2-1/2 and coated with Hi-built epoxy paints for marine environment and most industrial applications.
- Special painting to user specification is available upon request.
For any enquries?
Please Contact us
-
for AC 230 V, 50 cycles
- impellers 140 – 270 mm diameter
- air volume 150 – 1.260 m³/h
- also available in ex-proof version
For more information, please visit the Maico website.
For any enquries?
Please Contact us
-
AC 230V. 50/60Hz or 400V, 3 Phase 50/60Hz
- Available in 200mm to 1000mm diameter.
- IP 55 protection in most models.
- Options of aluminum or plastic impeller,
- Explosion proof – Increase safety to DIN, VDE and VDMA Standard are available.
For more information, please visit the Maico website.
For any enquries?
Please Contact us